Power Supply Voltage
In the section “Power supply voltage”:
In the field “Method of calculation”, select the parameter based on which Omnicomm Online software will record the terminal power supply voltage.
Possible values depending on the type of the terminal being connected:
• Main/additional power. This Method of calculation is set up if the third-party terminal is connected to the VH onboard network and backup battery. Omnicomm Online software will record the main power or additional power value depending on the parameter “Power supply status”;
• Main power supply. This Method of calculation is set up if the third-party terminal is connected to VH onboard network. Omnicomm Online software will record only the voltage value of the main power;
• Additional power supply. This Method of calculation is set up if the third-party terminal is connected to the backup battery. Omnicomm Online software will record only the voltage value of the additional power (i.e. the backup battery);
• Always 0 V. This Method of calculation is set up if it is not required to control the onboard network voltage and Omnicomm Online software will record the permanent value of the power supply voltage – 0.
• Analogue input <N>. This Method of calculation is set up if the analogue input of the third-party terminal is connected to the onboard network. Omnicomm Online software will record the voltage value when receiving a respective value from the third-party terminal;
• CAN parameter: SPN168. This Method of calculation is set up if the third-party terminal transmits the engine speed value from the bus CAN signal SPN168;
“The coefficient for reducing to 0.1 V” - enter the factor by which to multiply the received power supply voltage value to convert it to dimensions of 0.1 V;