Installation and connection

While installing the Omnicomm LLD-HD fuel volume indicator with the help of screws, drill two 3.2 mm diameter fixation holes according to the installation dimensions:

Scheme of connecting the <k style='word-break:keep-all;white-space:nowrap'>Omnicomm LLD-HD</k> indicator without a
connector

On the back side of a place of installation (e.g.dashboard, mounting plate etc.) install a washer and a nut, which are both included in the delivery set.

While installing the Omnicomm LLD-HD fuel volume indicator with the help of self-tapping screws, drill two 2.5 mm diameter fixation holes according to the installation dimensions.

Connection of Omnicomm LLD-HD display with Omnicomm LLS-HD sensor shall performed in accordance with the diagram:

Scheme of connecting the <k style='word-break:keep-all;white-space:nowrap'>Omnicomm LLD-HD</k> indicator with <k style='word-break:keep-all;white-space:nowrap'>Omnicomm LLS-HD</k> sensor

Purposes and colours of the wires in the cable of the Omnicomm LLD-HD indicator when connecting without a connector:

Name of signal Colour of wire
EIA-485 A Orange-white
EIA-485 B White-blue
Positive supply Brown
Ground (negative) supply White