Put a gasket on the probe of Omnicomm LLS-HD for the place of installation. Install the Omnicomm LLS-HD sensor in the fuel tank. Put the protective cover on.

Fasten the Omnicomm LLS-HD sensor:

  • When fastening with rivets, use the riveter.
  • When fastening with bolts, first put on the security seal on one bolt, spring washer and flat washer.
  • When fastening on plastic fuel tanks with wall thickness over 3 mm, use self-tapping screws and a security seal (for one selftapping screw) included in the installation kit.

Connect the product according to the diagram:

Scheme of connecting the <k style='word-break:keep-all;white-space:nowrap'>Omnicomm LLS-HD</k>

Wiring diagram:

Pin name Wire colour
RS-485 A Orange-white
RS-485 B Blue-white
RS-232 Tx Pink
RS-232 Rx Grey
+PWR Brown
Ground White