“Empty/Full” Calibration
When performing calibration and subsequent tank calibration using a single type of fuel, it is recommended to enable Auto Adjustment (see Sensor](https://doc.omnicomm.ru/ru/omnicomm_lls_6-manual/setting/set|Sensor) Configuration). Enable Auto Adjustment and save the settings to the fuel level sensor.
- Pour fuel into the measuring container.
- Immerse the Omnicomm LLS sensor into the fuel along the entire length of its measuring section.
- Wait for the green “Stabilized” indicator to appear.
Press the “Full” button — the value corresponding to a full tank will be recorded. - Remove the Omnicomm LLS sensor from the container and allow the fuel to drain from the measuring section for 1 minute. Press the “Empty” button — the value corresponding to an empty tank will be recorded.
- Press the “Write to Device” button.