Filtration Rating Setting (10h command)

This command is intended to determine the value of the filter’s length on Omnicomm LLS 30160 sensor.

Command format:

Offset, bytes Field size, bytes Value Description
0 1 3Eh Prefix
+1 1 00h..FFh Network address of the recipient
+2 1 0Fh Operation code
+3 1 00h..FFh Cheksum

Response format:

Offset, bytes Field size, bytes Value Description
0 1 3Eh Prefix
+1 1 00h…FFh The network address of the recipient
+2 1 10h Operation code
+3 16 LLS 30160¹ The name of the sensor. The type is a line constant. The value shall be set at the manufacturing plant during the PCB firmware.
+19 11 LLS 1.0.0.0¹ Designation of the program and its version
+30 1 00h…03h Data output mode
+31 1 00h…FFh Interval of measurement results output
+32 1 0…20 Filter length
+33 2 0…4095 The lower limit for changes in level
+35 2 1…4095 Upper limit for changes in level
+37 3 000000h…FFFFFFh CNT1 is the lower limit of the input signal period range
+40 3 000000h…FFFFFFh CNT2 is the upper limit of the input signal period range
+43 1 00h…FFh Checksum

¹ the name of the sensor, version number and firmware designation can be different from the given in the table.