| Parameters | Value |
|---|---|
| Power supply voltage, V | 7 – 45 |
| Power consumption, W | Nominal – 0.6 Maximum – 0.9 During a short-circuit on an analog output – 1.6 |
| Analog output: | |
| Output voltage range, V | 0…20 |
| Maximum output voltage, V | 5…20 |
| Minimum output voltage, V | 0…15 |
| Digital-to-analog conversion resolution, bit | 12 |
| Load resistance on analog output, Ohm | Not less than 2000 |
| Output signal pulsation, % | Not more than 0.15 |
| Frequency output: | |
| Output signal modulation | Frequency pulse |
| Output frequency range, Hz | 30…2000 |
| Maximum output signal frequency, Hz | 100…2000 |
| Minimum output signal frequency, Hz | 30…1900 |
| Maximum load current at the frequency output in the “open collector” mode, mA | 300 |
| Resistance of the internal “pull-up resistor” to positive voltage supply, Ohm | 1500 |
| General information: | |
| Measurement range, mm | 0…700, 1000, 1500 |
| Basic reduced error of level measurement, % | ±1 |
| Ambient temperature, °С | From -40 to +80 |
| Limit temperature, °С | -60 and +85 |
| Relative humidity at 25 °С (without moisture conden-sation), % | From 5 to 95 |
| Atmospheric pressure, kPa | From 84 to 107 |
| Maximum relative humidity at 25 °С (without moisture condensation), % | 100 |
| Ingress protection rating | IP69k |
| Operating mode | Continuous |
| Internal filter size | From 0 to 30 |
| Measurement time period, s | 1 |
| Overall dimensions, mm | 78×74×(24+length of the measuring probe) |
| Weight, kg | Not more than 2 |
| Average service life, years | 8 |