LLS Configuration
GPS Trackers Configuration
Omnicomm Profi 3.0
Prerequisites
Connectivity
Configuration
Network
LLS
RPM
Universal Inputs
CAN bus
Omnicomm Optim 3.0
Prerequisites
Connectivity
Configuration
Network
LLS
RPM
Universal Inputs
CAN bus
Omnicomm Profi Wi-Fi 3.0
Prerequisites
Connectivity
Configuration
Network
LLS
RPM
Universal Inputs
CAN bus
Teltonika FMC125
Prerequisites
qwerty 123
Connectivity
Configuration
Network
LLS
RPM
Universal Inputs
CAN bus
Teltonika FMC650
Prerequisites
Step 1: Install Software
- Download & install Teltonika Configurator for your OS:
- Install COM Port Drivers for PC communication:
Connectivity
Step 2: Fuel Sensor Connection
FMC 650 MOUNTING RECOMMENDATIONS
CONNECTING WIRES
- Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires.
- The connections should not be seen very clearly. If factory isolation was removed while connecting wires, it should be applied again.
- If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied.
- Wires cannot be connected to the board computers or control units.
CONNECTING POWER SOURCE
- Be sure that after the car computer falls asleep, power is still available on chosen wire. Depending on car, this may happen in 5 to 30 minutes period.
- When module is connected, measure voltage again to make sure it did not decrease.
- It is recommended to connect to the main power cable in the fuse box.
- Use 3A, 125V external fuse.
CONNECTING IGNITION WIRE
- Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
- Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
- Check if power is still available when you turn off any of vehicles devices.
- Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
CONNECTING GROUND WIRE
- Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
- If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
- For better contact scrub paint from the spot where loop is going to be connected.
RS485 Digital Sensors Connection
Connect Omnicomm LLS sensors to the RS485 (RJ45) port using the appropriate connector.*
*A cable with an RJ-45 connector is not included in the FMC650 delivery pack.
RS232 Digital Sensor Connection
Step 3: Connect FMC650 Tracker
3. Use the USB/2-USB cable or another suitable cable to connect the FMC650 tracker to your PC.*
*A cable with an USB/2-USB connector is not included in the FMC650 delivery pack.
4. Open Teltonika Configurator and wait for it to detect the connected device (1- 2 min). The configurator could restart after the recognition tracker.
Step 3: Network Configuration
5. When your device appears, enter the configuration window.
6. Go to the “System” tab.
Set ignition input:
- The ignition wire must be connected to AIN1 input.
- Under Ignition Source, select the corresponding AIN1 flag.
Under Data Protocol, select one of the following:
- Recommended: Codec 8 or Codec 8 Extended.
- Note: Choosing a protocol defines which port you'll configure in the GPRS tab.
Under Records Settings:
- Set Sort by: Oldest
10. Go to the GPRS tab.
Configure APN and password if required by your SIM card provider.
Under Server #1 Settings, enter:
- Domain: 185.9.185.254 or convert.omnicomm.ru
- Port:
- Codec 8 Professional: 15352
- Codec 8 Professional Extended: 15353
- Protocol: TCP
Step 4: LLS sensors Settings
RS485:
16. Open the RS232/RS485 tab.
17. Under RS485 Settings:
- Mode: LLS
- Baudrate: 19200 (must match sensor setting)
18. Under RS485 LLS Sensors:
- Set LLS 1 Address: 1
- Set LLS 2 Address: 2, etc.
- (Sensor IDs must match the ones configured on the LLS sensors.)
RS232:
19. Under RS232 Settings:
- Com 1 or Com 2 Mode: LLS
- Baudrate: 19200
20. Go to the I/O tab.
Set the priority of:
- LLS 1 Fuel Level – LLS 6 Fuel Level (must match sensors number)
- LLS 1 Temperature – LLS 6 Temperature (must match sensors number)
- Set each of these to LOW priority
In case of use Digital or Analog inputs, set the priority and range accordingly.
Step 5: Verify Readings
22. Go to the “Status” tab to confirm data:
- Check the I/O tab.
- Check GNSS info.
- Check GSM info to verify SIM/network connection and server data transmission:
Step 6: Add VH and verify Readings on the platform
23. Log in to your account and open Administration-Vehicles tab.
- Click Add.
- Choose Type of terminal: Teltonika Professional Codec 8 Ext.
- Server port will set automatically 15353 (must fit server port in “GPRS” tab).
- Put your device's IMEI number in Factory No field.
- Put the name in Vehicle Name field (this name will be displayed in reports).
24. Click on created VH in the list and click VH Profile button.
- Open Profile tab, set up settings according manual: https://doc.omnicomm.ltd/en/omnicomm_online-administration/vehicle/add/profile_settings
- In the Fuel parameters section, choose a number of tanks and number of installed LLS.
“Fuel tanks” - Select the number of fuel tanks installed on a vehicle:
- “Main only” means only one fuel tank is installed on a vehicle
- “Main and additional” means two fuel tanks are installed on a vehicle. For refuellers, the main tank is the reservoir, the additional tank is the engine fuel tank. For the vehicle, the main tank is the engine fuel tank, the additional tank is the fuel tank for the optional equipment.
- “Multitank” means up to 6 fuel tanks are installed on a vehicle. Available to users with established rights to objects: Access to Multitank (see Adding and editing a user profile).
Examples:
- Main tank and single sensor: Common scenario.
- Main tank and 2 sensors and more: In case of a complicated shape or impossibility to install a sensor in the center, two or more sensors are used for measurement level in a single tank.
- Main and additional tank and 2 sensors: A Vehicle has 2 tanks, and each tank is equipped with 1 sensor.
- Main and additional tank and 3 or more sensors: A Vehicle has 2 tanks, and each tank is equipped with 1 or more sensors.
- Main tank + Multitank or Main and additional tank + Multitank is scenarios for fuel bowser, gas stations e.t.c. For each cistern or isolated compartment could be assigned one or several sensors.
For each tank set up Parameters of the fuel tank:
- Set up Refueling threshold (recommended value 7% of tank volume, number depends on condition);
- Set up Fuel draining threshold (recommended value 7% of tank volume, number depends on condition);
- Set up Rough filter (depends on road condition);
- Set up Buffer length (depends on road condition);
- In Editing the calibration tables, import calibration tables or fill it manually and link sensors to the tanks.
25. Open Parameter settings tab:
- Choose and link the necessary parameters.
- For CHECK FUEL LEVEL SENSOR choose sourse of data for each LLS:
For Fuel level sensor 1:
- Calculation method: LLS1 Level
- Determining method for the fuel level sensor condition: Calculate
- Level is 0: Mode = Ready
- Level above 4095: Mode = Error
- Fuel temperature Calculation method: LLS1 Temperature
For Fuel level sensor 2:
- Calculation method: LLS2 Level
- Determining method for the fuel level sensor condition: Calculate
- Level is 0: Mode = Ready
- Level above 4095: Mode = Error
- Fuel temperature Calculation method: LLS2 Temperature
Same for each sensor.
- Click Save and recalculate.
26. Choose VH in the list and click VH Profile button.
- Open Monitoring tab: check the received values.