Installation and Connection
While installing the Omnicomm LLD fuel volume indicator with the help of screws, drill two 3.2 mm diameter fixation holes according to the installation dimensions, on the back side of a place of installation install a washer and a nut, which are both included in the delivery set:
While installing the Omnicomm LLD fuel volume indicator with the help of self-tapping screws, drill two 2.5 mm diameter fixation holes according to the installation dimensions.
The connection the Omnicomm LLD indicator to the Omnicomm LLS sensor, terminal or on-board network of the vehicle is generated according to the scheme :
If it is necessary to connect two Omnicomm LLS sensors, it is recommended to use two KTZ splitters and two KTZ cables.
Purposes and colors of the wires in the installation cable:
Name of signal | Type of wire |
---|---|
RS-485 A | Orange-white |
RS-485 B | White-blue |
RS-232 Tx | Pink |
RS-232 Rx | Gray |
+V power | Brown |
Ground | White |
Purposes and colors of the wires in the cable of the Omnicomm LLD indicator when connecting without a connector:
Name of signal | Type of wire |
---|---|
RS-485 A | Orange-white |
RS-485 B | White-blue |
+V power | Brown |
Ground | White |