In the tab “Settings” under “Custom parameters”:

“Filtration” and “Severe operating conditions” parameters can be set similarly to Omnicomm LLS 30160 sensors.

“Type of signal” - choose between “Analog” or “Frequency”.

For the analog signal:

  • “Max. voltage value (5 … 20) V” - set the maximum voltage value. Default value – 5 V.
  • “Min. voltage value (0 … 15) V” - set the minimum voltage value. Default value – 0 V.

For the frequency signal:

  • “Max. frequency value (100 to 2000) Hz” - set the maximum frequency value. Between 100 and 1053 Hz, when connecting to Omnicomm terminals. Default value – 2000 Hz.
  • “Min. frequency value (30 to 1900) Hz” - set the minimum frequency value. Default value – 30 Hz.
  • “Pull-up resistor”. Select “On” if, according to the manufacturer's instructions, the voltage signal is connected to the input of an external device. Select “Off” if the type of the connected signal is “dry contact” or “transistor NPN key”.