Fuel Tank Preparation

1. Select the location for Omnicomm LLS 4 sensor installation subject to the following requirements:

  • Installation location should be as close as possible to the geometric center and placed at the deepest level of the tank:

Select the location for Omnicomm LLS installation

  • When installed, the sensor should not be in contact with reinforcement ribs inside the tank
  • Installation of two sensors in one tank allows for significant reduction of the fuel level dependence on the vehicle inclination angle:

Installation location of Omnicomm LLS

2. Steam out the tank to ensure compliance with the safety rules

3. Drill out the central bore by bimetal core drill ø35 mm

4. Drill out four mounting holes according to the diagram:

Preparing the installation location for Omnicomm LLS

The mounting hole diameter depends on the tank material:

  • ø 4 mm – for metal tank with wall thickness over 3 mm (cut M5 thread)
  • ø 7 mm – for plastic and metal tank with wall thickness up to 3 mm (for rivets)
  • ø 4 mm – for plastic tank with wall thickness over 3 mm