Selection of Ignition Source
In the «Settings» tab select the «Inputs» section from the list.
In the «Ignition key status» section: «Data source» – select the data to register ignition on/off.
«Onboard voltage» – the ignition on is registered upon reaching the vehicle network power supply threshold voltage.
«Threshold voltage» value: when this value is reached, the ignition will register as switched on. Ignition off is registered, when the voltage drops to 0,5 V below the threshold. Default value – 13,5 V.