OBD Bus
In the «Settings» tab select the «OBD» section from the list.
In the «OBD Parameters» section:
Default OBDII parameters are not selected.
From the list of parameters, choose the ones you wish to display the value of in Omnicomm Online and check the corresponding boxes.
List of parameters:
- Check Engine Error
- Revolutions, rpm
- Speed, km/h
- Fuel volume, %
- Mileage after Maintenance, km
- Coolant temperature,°С
- Voltage, V
- Time to Maintenance, min
- Oil temperature,°С
- Instant fuel consumption, L/h
Value — parameter value obtained from the terminal.
OBD parameters tab to SAE J1979, SAE J1939
Parameter | Protocol | |||
---|---|---|---|---|
SAE J1979 | SAE J1939 | |||
SID | PID | PGN | SPN | |
Check Engine Error | 0*01 | 0x01 | FECA | 1213 |
Revolutions, rpm | 0*01 | 0x0C | F004 | 190 |
Speed, km/h | 0*01 | 0x0D | FEF1 | 84 |
Fuel volume, % | 0*01 | 0x2F | FEFC | 96 |
Mileage after Maintenance, km | 0*01 | 0x31 | - | - |
Coolant temperature,°С | 0*01 | 0x05 | FEEE | 110 |
Voltage, V | 0*01 | 0x42 | FEF7 | 168 |
Time to Maintenance, min | 0*01 | 0x4E | - | - |
Oil temperature,°С | 0*01 | 0x5C | FEEE | 175 |
Instant fuel consumption, L/h | 0*01 | 0x5E | FEF2 | 183 |
SID – Channel ID by SAE J1979.
PID – Parameter ID to SAE J1979.
PGN – No. of parameters group, defining the contents of the corresponding message according to SAE J1939.
SPN – code of the parameter according to SAE J1939.