Changing network address

To change the network address of an LLS sensor, follow the steps below:

1. Open the Omnicomm Configurator application and connect to the LLS sensor.

2. In the settings menu, locate the field “Network address.”

3. Set the network address of the LLS fuel level sensor to a value between 1 and 254. The network address of each Omnicomm LLS sensor connected to the same external device must be unique.

When connecting multiple Omnicomm LLS sensors to an Omnicomm terminal, assign the value 1 to the first sensor, and then continue in ascending order for the remaining sensors.

4. After entering the correct value, tap OK to save the new network address.

The LLS sensor will now operate using the updated network address.