Configuration of Omnicomm LLS 4 sensors

Set up configuration parameters as described below:

Address (from 1 to 254) – set the network address of the Omnicomm LLS fuel level sensor. When several sensors are connected to one external device, the network addresses must be unique.

Auto output – select:

  • No output – autonomous data output (without request) is not performed.
  • Binary – autonomous data output in binary format.
  • Character – autonomous data output in character format.
  • Data output interval (from 1 to 255 seconds) – set the interval for autonomous data output.

Min level (from 0 to 1023) – select the minimum reading of the LLS fuel level sensor. The default value is 0.

Max level (from 1 to 4095) – select the maximum reading of the LLS fuel level sensor. The default value is 4095.

Baud rate - select the speed at which data exchange with the external device will be performed. The default value is 19200 bit/s.

Filtering – set the output signal filtering parameters:

  • None – no filtering is applied. Used when filtering is performed by an external device.
  • Minimum – filtering is used when installed in stationary fuel storage tanks and low-mobility equipment.
  • Medium – filtering is used when the vehicle operates under normal road conditions.
  • Maximum – filtering is used when the vehicle operates under harsh road conditions.

Heavy exploitation conditions - it is recommended to keep this setting ON when the vehicle frequently operates under harsh conditions. For normal road conditions, this setting can remain OFF to allow faster response times.