Спасибо!

Мы исправим ошибку в ближайшее время

Сообщить об ошибке

Site Tools


Configuration of Omnicomm LLS 4 AF sensors

Set up configuration parameters as described below:

On the “Settings” tab, in the “Configurable parameters” section:

Filtering – set the output signal filtering parameters:

  • None – no filtering is applied. Used when filtering is performed by an external device.
  • Minimum – filtering is used when the device is installed in stationary fuel storage tanks and low-mobility equipment.
  • Medium – filtering is used when the vehicle operates under normal road conditions.
  • Maximum – filtering is used when the vehicle operates under harsh road conditions.

Signal type – select Analog or Frequency.

For an analog signal:

  • Max. voltage value (5 … 20) V – set the maximum voltage value. The default value is 5 V.
  • Min. voltage value (0 … 15) V – set the minimum voltage value. The default value is 0 V.

For a frequency signal:

  • Max. frequency value (100 to 2000) Hz – set the maximum frequency value. The default value is 2000 Hz.
  • Min. frequency value (30 to 1900) Hz – set the minimum frequency value. The default value is 30 Hz.

When connected to Omnicomm terminals, the configured maximum and minimum frequency values must be within the range from 30 to 1053 Hz

  • Pull-up – if, according to the manufacturer’s description, a voltage signal is connected to the input of the external device, select On. If a “dry contact” signal or an NPN transistor switch is connected, select Off.